Specifications

Arc 380 Specifications
Project NameARC 380
DeveloperTong Eng Brothers
ArchitectDP Architects
Site AreaTBA
No. Of Units144 Office Units and 23 Shops
District08
TenureFreehold
Expected TOP31st Dec 2018
Carpark82 Carpark (inclusive of 2 handicap lots)
Unit Types
  • Restaurants: 34 to 77 sqm (TBA Units)

  • Shops: 21 to 44 sqm (TBA Units)

  • Offices: 66 to 93 sqm (144 Units)
  • RETAIL SPECIFICATIONS

    1) FOUNDATION
    Reinforced concrete bored piles and/or other approved foundation system

    2) STRUCTURE
    Reinforced concrete structures/steel structures

    3) ROOF
    Reinforced concrete flat roof with appropriate waterproofing and insulation system

    4) CEILING
    Restaurant/Shop Units
    -Skim coat
    Common Area
    -Plasterboard and/or moisture resistant ceiling boards and/or cement and sand plaster and/or skim coat with paint where applicable.

    5) WALL
    External: Frameless shopfront glass and aluminium frame with glass door and/or concrete and/or blockwall shall be provided for units #01-01, #01-02, #01-03, #01-06, #01-07, #01-08, #01-09, #01-10, #01-11, #01-12, #01-20, #01-21, #01-22 & #01-23.
    Roller shutters (in lieu of aluminium frame and glass shopfront) shall be provided for units #01-04, #01-05, #01-13, #01-14, #01-15, #01-16, #01-17, #01-18 & #01-19 to create an open concept effect for these Units.
    Internal: Concrete and/or brickwall and/or blockwall and/or prefabricated panels and/or drywall partition system.

    6) WALL FINISHES
    Restaurant/Shop Units
    -Cement and sand plaster and/or skim coat with paint where applicable
    Common Area
    -Homogeneous tiles and/or cement and sand plaster and/or skim coat with paint finish where applicable

    7) FLOOR FINISHES
    Restaurant/Shop Units
    -Cement and sand screed
    Common Area
    -Natural stone and/or homogeneous tiles and/or carpet and/or composite timber and/or cement and sand screed

    8) DOORS
    Framed glass door with lockset shall be provided for units #01-01, #01-02, #01-03, #01-06, #01-07, #01-08, #01-09, #01-10, #01-11, #01-12, #01-20, #01-21, #01-22 & #01-23

    9) ACMV
    Restaurant/Shop Units
    Individual aircooled VRV air-conditioning system is provided. Condensor units are located on the 4th storey/roof of car park ramp on the respective accessory lots of each Unit. Refrigerant pipes from condensor unit terminate in the fan coil unit/s provided within the Units. The Purchaser shall run own distribution branch ducts and supply outlets to suit the Units’ layout. The Purchaser shall maintain/replace the entire air conditioning system serving his Unit at his own costs and pay for the electrical consumption by tapping the supply from the Purchaser’s electrical meter.

    Common Area
    Retail Corridor (1st storey), Carpark Lift Lobby (2nd-4th storey) – Fully air-conditioned in accordance to the operating hours of the Restaurant/Shop Units.

    10) ELECTRICAL INSTALLATION
    Refer to M&E schedule for details.

    11) PLUMBING AND SANITARY
    Restaurant Units
    Floor trap and water-tap off point are provided to all Units. Floor traps are connected to centralised grease traps.

    Shop Units
    Floor trap and water-tap off point are provided to all Units.

    Common Area
    Good quality sanitary wares and fittings in compliance with statutory requirements.

    12) FIRE PROTECTION SYSTEM
    Provided in compliance with relevant authority requirements

    13) KITCHEN EXHAUST & SUPPLY AIR
    Restaurant Units
    Kitchen Exhaust: Common exhaust ducts for the kitchen are provided up to the back of the Restaurant Units. Regular maintenance, cleaning, servicing and replacement of the ductworks within the Unit will be the responsibility of the Purchaser.

    Kitchen Supply Air: Supply air ducts and fans for the kitchen are provided up to the back of the Restaurant Units. Regular maintenance, cleaning, servicing and replacement of the ductworks and fans within the Unit will be the responsibility of the Purchaser. Electrical consumption for the supply air fans will be borne by the Purchaser and the electrical supply will be tapped from the electrical meter of the Purchaser’s Unit.

    Kitchen hoods and associated fire suppression system within Restaurant Unit’s kitchen shall be installed by the Purchaser at his own costs and must comply to NEA requirements.

    14) TOWN GAS SUPPLY
    Restaurant Units
    Gas pipe is provided and terminated within the unit. Purchaser to apply to City gas for gas meter and connection at his own cost and expenses.

    15) CABLE TELEVISION SYSTEM
    Cable television points to be provided within Restaurant/Shop units.

    16) TELEPHONE SYSTEM
    Optical Fibre Cable System to COPIF: 2013 for Shops/Restaurant Units complete with FTP (Fibre Termination Point) and patch panel

    17) LIGHTNING PROTECTION
    Lightning protection provided in compliance with relevant authority requirements.

    18) LIFTS
    1 car park lift serving 1st to 4th storey
    4 passenger lifts serving 1st storey to 16th storey
    1 passenger lift serving 1st storey to Roof Level
    1 Fire lift serving 1st storey to Roof Level

    19) FLOOR LOADING
    Live Load = 5.0 kN/m2

    20) WATERPROOFING
    Waterproofing to floors of roof terrace, sky terrace, swimming pool, pool deck, toilets and reinforced concrete flat roof where applicable

    21) DRIVEWAY, CARPARK AND PEDESTRIAN COVERED WALKWAY
    Entrance driveway/drop off plaza: Natural stone and/or homogeneous tiles
    Pedestrian covered walkway: Natural stone and/or homogeneous tiles and/or wash pebble
    Carpark, carpark ramp/driveway: Reinforced concrete slab with floor hardener

    22) RECREATIONAL FACILITIES AND COMMUNAL AREAS
    -Office Entrance/Drop-Off
    -Water Feature with Sculpture
    -Sky Terraces – 6th to 16th Storey
    -Landscape Deck
    -4th Storey Sky Terrace
    -BBQ Area
    -Landscape Deck
    -Water Feature
    -Roof Terrace
    -Gymnasium
    -Function Room
    -Lap Pool
    -Pool Deck
    -Pool Lounge

    23) ADDITIONAL ITEMS
    Flood Barrier
    Flood barriers are provided for #01-01, #01-02, #01-03, #01-06, #01-07, #01-08, #01-09, #01-10, #01-11, #01-12, #01-20, #01-21, #01-22 & #01-23 in compliance with the requirements of the relevant authorities to avoid flooding of the premises arising from flooding in the vicinity. The Purchaser shall familiarise himself with the operations of the flood barrier and operate the flood barriers within his own premises when the need arises. The Purchaser shall store and maintain the flood barriers for his own premises. There will be water seepage at the rate of 1 litre per hour per meter length through the flood barrier by default.
    Flood barriers are provided for Office Main Lobby, Retail Entrances, Retail Service Entrance in compliance with the requirements of the relevant authorities to avoid flooding of the common area arising from flooding in the vicinity. The management of the common area shall familiarise itself with the operations of the flood barrier and operate the flood barriers within the common area when the need arises. The management of the common area shall store and maintain the flood barriers for the common area. There will be water seepage at the rate of 1 litre per hour per meter length through the flood barrier by default.

    OFFICE SPECIFICATIONS

    1) FOUNDATION
    Reinforced concrete bored piles and/or other approved foundation system

    2) STRUCTURE
    Reinforced concrete structures/steel structures

    3) ROOF
    Reinforced concrete flat roof with appropriate waterproofing and insulation system

    4) CEILING
    Office Units
    -Skim coat
    Office Unit Toilets
    -Moisture resistant ceiling boards
    Common Area
    -Solid surface panel and/or mineral fibre ceiling and/or plasterboard and/or skim coat with paint where applicable

    5) WALL
    External: Aluminium glass curtain wall and/or aluminium cladding system with/without aluminium screening and/or concrete and/or brickwall
    Internal: Concrete and/or brickwall and/or blockwall and/or glass panel and/or pre-fabricated panels and/or drywall partition system

    6) WALL FINISHES
    Office Units
    -Cement and sand plaster and/or skim coat with paint where applicable
    Office Unit Toilets
    -Homogeneous tiles and glass panel up to 2.4m height only (the internal block wall/glass panel/partitions of the toilets will be built up to a height of 2.4m).
    Common Area
    -Natural stone and/or homogeneous tiles and/or glass panels with stainless steel strips and/or laminate and/or cement and sand plaster and/or skim coat with paint finish where applicable

    7) FLOOR FINISHES
    Office Units
    -Cement and sand screed
    Office Unit Toilets
    -Homogeneous tiles
    Common Area
    -Natural stone and/or homogeneous tiles and/or carpet and/or composite timber and/or cement and sand screed

    8) CURTAIN WALL
    Aluminium framed curtain wall system with heat strengthened, low-E double glazing.

    9) DOORS
    Office Units
    -Framed glass door with lockset
    Office Unit Toilets
    -Powder coated aluminium framed glass sliding door

    10) ACMV
    Office Units
    Chilled air conditioning for the office floors is provided by a central water cooled chiller system. Chilled water is piped into individual fan coil units (FCU) in the Office Units from which cold air is supplied through a duct running from the FCU to the rear of the Unit.Extensions/modifications of ductworks within the Units to suit the Unit layouts shall be carried out by the Purchaser at his own costs. The Purchaser shall maintain/replace the FCUs and ductworks within his Unit at his own costs. Electrical supply to the FCU will be tapped off from the electrical meter of the Purchaser’s Unit. The normal operating hours of the central chiller system are between 8am to 6pm, from Mondays to Fridays, excluding Public Holidays. Aircon ledge is provided in each Office Unit. The Purchaser may install his own air-cooled split unit airconditioning system at his own cost to enjoy air-conditioning beyond the normal hours of operation of the central air-conditioning system. Mechanical ventilation to Office Unit Toilets comply with authority requirements. Mechanical ventilation fans and ducts within Office Unit Toilets will be maintained/replaced by the Purchaser at his own costs. Electrical supply to fans will be tapped off from electrical supply of the Purchaser’s Unit.

    Common Area
    Typical Office Floor Lift Lobby & Common Corridor, Carpark Lift Lobby
    (2nd – 4th storey), Main Entrance Office Lobby (1st storey) – Fully air conditioned.

    11) ELECTRICAL INSTALLATION
    Refer to M&E schedule for details.

    12) PLUMBING AND SANITARY
    Office Unit Toilet
    -1 shower screen with shower mixer and handset, 1 basin c/w tap mixer, 1 pedestal water closet, 1 mirror and 1 toilet roll holder
    Common Area
    -Good quality sanitary wares and fittings in compliance with statutory requirements.

    13) WATER SUPPLY
    Hot and cold water supply provided

    14) FIRE PROTECTION SYSTEM
    Provided in compliance with relevant authority requirements

    15) CABLE TELEVISION SYSTEM
    Cable television tap-off box provided in the riser duct at the common corridor.

    16) TELEPHONE SYSTEM
    Optical Fibre Cable System to COPIF: 2013 for Office Units complete with FTP (Fibre Termination Point) and patch panel

    17) LIGHTNING PROTECTION
    Lightning protection provided in compliance with relevant authority requirements.

    18) LIFTS
    1 carpark lift serving 1st to 4th storey
    4 passenger lifts serving 1st to 16th storey
    1 passenger lift serving 1st storey to Roof Level
    1 Fire lift serving 1st storey to Roof Level

    19) FLOOR LOADING
    Live Load = 4.0 kN/m2

    20) WATERPROOFING
    Waterproofing to floors of roof terrace, sky terrace, swimming pool, pool deck, toilets and reinforced concrete flat roof where applicable

    21) DRIVEWAY, CARPARK AND PEDESTRIAN COVERED WALKWAY
    Entrance driveway/drop off plaza: Natural stone and/or homogeneous tiles
    Pedestrian covered walkway: Natural stone and/or homogeneous tiles and/or wash pebble
    Carpark, carpark ramp/driveway: Reinforced concrete slab with floor hardener

    22) RECREATIONAL FACILITIES AND COMMUNAL AREAS
    -Office Entrance/Drop-Off
    -Water Feature with Sculpture
    -Sky Terraces – 6th to 16th Storey
    -Landscape Deck
    -4th Storey Sky Terrace
    -BBQ Area
    -Landscape Deck
    -Water Feature
    -Roof Terrace
    -Gymnasium
    -Function Room
    -Lap Pool
    -Pool Deck
    -Pool Lounge

    23) ADDITIONAL ITEMS
    Flood Barrier
    Flood barriers are provided for Office Main Lobby, Retail Entrances, Retail Service Entrance in compliance with the requirements of the relevant authorities to avoid flooding of the common area arising from flooding in the vicinity. The management of the common area shall familiarise itself with the operations of the flood barrier and operate the flood barriers within the common area when the need arises. The management of the common area shall store and maintain the flood barriers for the common area. There will be water seepage at the rate of 1 litre per hour per meter length through the flood barrier by default.